Brief introduction
Tricolor temperature measurement technology is based on the visual wavelength of red, green, blue, which can be received by color CCD, the ratio solve method. It belongs to two color range essentially. The method not only has the characteristics of simple, a normal two color calibration. But also, radiation image can be shown under different wavelength, but the same color image. Thus, it is avoid the difficult of getting a radiation image under different wavelength but the same burning material. So the double cylinder actuator system is quite suitable for some high sealed requirement condition, like blast furnace.
Features:
Multipoint temperature measurement: any points can be chosen to measuring
Double cylinder protection: all-in-one cylinder actuator, sealed ball valve
Coaxial video temperature control: to add control & temperature signal on video cable
LCD display control box: 7’’ high LCD will help operation and maintenance
Housing inside temperature: probe inside temperature will shown on the monitor
Pyrometer indication
Camera indication
Temperature range
800~2500 ℃
Analog resolution
1200 lines
Temperature accuracy
±1%
Optical zoom
5~10 times
Temperature resolution
1℃
Communication mode
Coaxial video temperature control
Points number
1~16
auto-protection
Pneumatic withdraw/adjust the valve
Testing mode
Instantaneous value/max.value/
average value
Max temperature inside furnace
2000 ℃
Coaxial output
1-4 path output
4-20mA
Cooling mode
Air cooling or air and water cooling
D:S
120:1
Air inlet pressure
0.3MPa
Testing distance
0.1~∝ meter
Air consumption
≈15m³/h